1Ph-1Ph 5KVA to 50KVA Air-Cooled & Oil-Cooled Servo

AC  Mainline voltage is unpredictably fluctuating in single phase & Three Phase Line, Our observation is, Variation in Mainline in a. Single phase from 100VAC to 300VAC( L/N) & in Three Phase the line variation is from : 240V to 500VAC ( L/L)

This fluctuation results into Low efficiency of the Load & equipments, Line Losses, Poor Power factor, Winding burn out, Armatures Failure & Lighting equipments wont give the desired result  .

Electric distribution is purely the Demand & supply match theorem, If it wont match fluctuation is bound to happen. Other reasons are improper cable selection, Loose connections etc. Fluctuation means the very Low , Low, Normal, High & Very High Line Voltage .

Due to Fluctuation either Low Voltage or High Voltage : We shall have the consequences

1. Frequent breakdown of the Electrical appliances : Motors/Furnaces/ Electronics/ Compressors etc

Although for partial Power stability is advised through IPFC or Capacitor in Inductive load, but its effectiveness also depends on the stable Voltage & that shall be perceived by the Servo Voltage Stabilizer.

Yes ! I am Interested

 

Types

1Ph  I/P &  1 Ph O/P  (P+ N+G)

  • Air cooled  Type
  • Oil Cooled Type

         Ranges up to : 75 KVA

 

 3 Ph  I/P & 3Ph O/P ( 3P+N+G)

  • Air cooled  UB Type
  • Oil cooled  UB Type

          Ranges Upto 3000 KVA

3Ph I/P (Delta) &  1Ph O/P  (P+N+G)

  • Aircooled 
  • Oilcooled

Ranges upto 1000 KVA

    ( Servo with integrated UIT )

It is made in regular model & also customized after your Load study to get the perfect result. Input Fluctuation range . The utility load detain , harmonic content these shall be the actual guideline to decide  the range & capacity as per IS 9815 Servo Construction norm

Purpose
  • Effectively control the voltage variation & fluctuations to prevent the damages of High Tech Instruments.
  • Excellent Energy saver device and recommended by BEE as Energy saver for Lighting Load applications
  • Value added Servo effectively controls the Transient Surges/Inrush current/High Voltage & Low Voltage protections subject to dedicated earthing.
  • Excellent neutral fault protections
  • Excellent Earth Fault protections
  • Transforming the infinite Raw Electrical Power into Finite protected Power
Salient Technical  Features
  • Analog / Microcontroller based Power corrector device with excellent protection with Instantaneous High Voltage/ Low Voltage/ Overload/Single phasing prevention/Reverse Phase protections/ Transient Surge suppressor (optional TVSS )
  • Stable output even under unbalanced voltage condition & Unbalanced load condition
  • Customized Input & Output voltage as per site and machines requirement.
  • Integrated Isolation Transformer  (optional) available with1.  1 Ph Input & 1Ph Output   2. 3 Ph Input , 3 Ph  Output  &  3.   3 Ph Input  &  1 Ph Output
  • Ratings available from 1 KVA to 3000KVA (Dimmer & Buck boost based with Rolling system)
  • Fast correction rate up to 70V/sec, Line to Line & 25V/Sec for 100KVA & above.
  • Response time of < 10 mSec
  • Use of PI control circuit or Microcontroller circuit prevents over/under shooting or hunting.
  • Plug –in type Glass epoxy control cards for ease serviceability.
  • Visual indication/protection against extreme Low & High Voltage conditions
  • Ruggedized construction, castor –mounted for easy movement
  • No waveform distortion, suitable for operation on DG set.
  • Auto/manual facility of operation from front panel controls.
  • Custom –built specification and all India service Network to meet OEM requirements
  • Optional built – in Ultra Isolation Transformer in normal/star –delta configuration
  • Power Saving up to 20% in Lighting Loads ( Condition applies).
  • Very effective in supporting the quality power
  • Designed for 24* 7* 365 cycle
  • Reduces overall maintenance cost by 80%
  • Payback period anticipated by 24 to 36 months
  • Life guarantee above 15 years
  • 80% depreciation
  • You can get the technical note on demand how power saving effectively works.
  • Entire Plant control by servo Voltage Regulators
  • CNC Machines/Plastic moulding machines/Spark Erosion & wirecut machines/
  • Residential applications
Applications :

 Rice & Flour Mills , Steel Industry, Machinery Industry, CNC Machines, Laser cutting Machines , Farm Houses & Resorts, Hospitals, Hotels, Show Rooms , Manufacturing Industries, Textile Industries, Commercial buildings , AirLines, Gyms, Hydarulic machines, AC Plants, Call Centers Petrol Pumps, CNG stations and many more,

General :

Servo Voltage Stabilizer also called as Main Line Voltage corrector, Automotic Voltage Controller, SCVS,  Power  Corrector device  using synchronous motor in close loop control . It senses the Input variable voltage constantly through Microcontroller circuit and proportional voltage generates in buckboost and that adding & substracting is constantly monitoring by the closed loop system and regulated voltage given in output and get monitored by the display system construction is rigidly followed the IS 9815 norms

Servo Is facilitated by Auto & Manual Mode for self test purpose or for any customized applications.

Sr No

               Parameters

   Single Phase Servo

1Ph IN 1Ph O/P( P+N+G)

Three Phase Servo

1. 3Ph IN 3Ph O/P  ( 3P +N+G)

 2. 3Ph IN  (3P+N+G) &  1Ph O/P  (P+N+G)

1

      Capacity of Servo

Air cooled :  3 to 30 KVA

Oil cooled :  10 KVA to 75 KVA

Air cooled : 6 KVA to 75 KVA

Oil cooled : 30 KVA to 3000KVA

2

   Input Ranges  ( Fluctuation Range)

170 V to 280VAC

140 V to 300VAC

110VAC to 310VAC

340 VAC to 480VAC

300VAC to 500VAC

280VAC to 500VAC

260VAC to 500 VAC

240 VAC to 500VAC

3

Nominal Output Voltage

 230VAC

400/415 VAC Selectable

4

Output Voltage accuracy

±   1%

±   1%

5

Input Line frequency Variation

 47Hz to 53 Hz

47Hz to 53 Hz

6

Effect of Power Factor

  None

 None

7

Waveform Distortion

None Added (Same as Input)

None added ( Same as Input)

8

Control

Digital / Analogue

 Digital/ Analogue

9

Response Time

  10 msec

 10 msec

10

Voltage Correction Rate with Synchronous Motor

1 Air cooled

2 Oil cooled

 

 

  25V/Sec

  15V/Sec

 

 

 25V/Sec

 15V/Sec

11

LCD Display

Input Voltage , Output Voltage (L to L & L to N)

Phase wise current monitoring

12

Log book Memory ( Non Volatile)

  • No of Hrs of operation on mains peak current demand
  • No of abnormal High Voltage cutoff events
  • No of abnormal Low voltage cutoff events

13

Programmble Features ( By passwords)

  • HV cut-off Set
  • LV cut-off Set
  • O/L Trip Set
  • Time Delay Set
  • Operating mode ( Auto / Manual)

14

Cooling

1 Air  cooled

2. Oil cooled

 

     3 KVA to 75 KVA & Above

     10 KVA to 3000 KVA

15

Efficiency

    97 to 98%

16

Protections

Protection of all control parameters are through INPUT MCCB with Shunt release coil/ Output contactor in Lower capacity and cutoff protections available for

  • Input High & Low Voltage cutoff
  • Output Overvoltage & Under Voltage cutoff
  • Overload & short circuit protections
  • Single Phasing & Phase Loss Trip
  • Reverse Phase protections
  • Neutral fault protections
  • Earth Fault Protections

17

Class C/ TVSS Transient & Surge protections

  • Type 1+2 Type protections with UL 1449 CE compliances with guideline of earthings

3Ph-3Ph 10KVA to 75KVA Air-Cooled Servo

AC  Mainline voltage is unpredictably fluctuating in single phase & Three Phase Line, Our observation is, Variation in Mainline in a. Single phase from 100VAC to 300VAC( L/N) & in Three Phase the line variation is from : 240V to 500VAC ( L/L)

This fluctuation results into Low efficiency of the Load & equipments, Line Losses, Poor Power factor, Winding burn out, Armatures Failure & Lighting equipments wont give the desired result  .

Electric distribution is purely the Demand & supply match theorem, If it wont match fluctuation is bound to happen. Other reasons are improper cable selection, Loose connections etc. Fluctuation means the very Low , Low, Normal, High & Very High Line Voltage .

Due to Fluctuation either Low Voltage or High Voltage : We shall have the consequences

1. Frequent breakdown of the Electrical appliances : Motors/Furnaces/ Electronics/ Compressors etc

Although for partial Power stability is advised through IPFC or Capacitor in Inductive load, but its effectiveness also depends on the stable Voltage & that shall be perceived by the Servo Voltage Stabilizer.

Yes ! I am Interested

 

Types

1Ph  I/P &  1 Ph O/P  (P+ N+G)

  • Air cooled  Type
  • Oil Cooled Type

         Ranges up to : 75 KVA

 

 3 Ph  I/P & 3Ph O/P ( 3P+N+G)

  • Air cooled  UB Type
  • Oil cooled  UB Type

          Ranges Upto 3000 KVA

3Ph I/P (Delta) &  1Ph O/P  (P+N+G)

  • Aircooled 
  • Oilcooled

Ranges upto 1000 KVA

    ( Servo with integrated UIT )

It is made in regular model & also customized after your Load study to get the perfect result. Input Fluctuation range . The utility load detain , harmonic content these shall be the actual guideline to decide  the range & capacity as per IS 9815 Servo Construction norm

Purpose
  • Effectively control the voltage variation & fluctuations to prevent the damages of High Tech Instruments.
  • Excellent Energy saver device and recommended by BEE as Energy saver for Lighting Load applications
  • Value added Servo effectively controls the Transient Surges/Inrush current/High Voltage & Low Voltage protections subject to dedicated earthing.
  • Excellent neutral fault protections
  • Excellent Earth Fault protections
  • Transforming the infinite Raw Electrical Power into Finite protected Power
Salient Technical  Features
  • Analog / Microcontroller based Power corrector device with excellent protection with Instantaneous High Voltage/ Low Voltage/ Overload/Single phasing prevention/Reverse Phase protections/ Transient Surge suppressor (optional TVSS )
  • Stable output even under unbalanced voltage condition & Unbalanced load condition
  • Customized Input & Output voltage as per site and machines requirement.
  • Integrated Isolation Transformer  (optional) available with1.  1 Ph Input & 1Ph Output   2. 3 Ph Input , 3 Ph  Output  &  3.   3 Ph Input  &  1 Ph Output
  • Ratings available from 1 KVA to 3000KVA (Dimmer & Buck boost based with Rolling system)
  • Fast correction rate up to 70V/sec, Line to Line & 25V/Sec for 100KVA & above.
  • Response time of < 10 mSec
  • Use of PI control circuit or Microcontroller circuit prevents over/under shooting or hunting.
  • Plug –in type Glass epoxy control cards for ease serviceability.
  • Visual indication/protection against extreme Low & High Voltage conditions
  • Ruggedized construction, castor –mounted for easy movement
  • No waveform distortion, suitable for operation on DG set.
  • Auto/manual facility of operation from front panel controls.
  • Custom –built specification and all India service Network to meet OEM requirements
  • Optional built – in Ultra Isolation Transformer in normal/star –delta configuration
  • Power Saving up to 20% in Lighting Loads ( Condition applies).
  • Very effective in supporting the quality power
  • Designed for 24* 7* 365 cycle
  • Reduces overall maintenance cost by 80%
  • Payback period anticipated by 24 to 36 months
  • Life guarantee above 15 years
  • 80% depreciation
  • You can get the technical note on demand how power saving effectively works.
  • Entire Plant control by servo Voltage Regulators
  • CNC Machines/Plastic moulding machines/Spark Erosion & wirecut machines/
  • Residential applications
Applications :

 Rice & Flour Mills , Steel Industry, Machinery Industry, CNC Machines, Laser cutting Machines , Farm Houses & Resorts, Hospitals, Hotels, Show Rooms , Manufacturing Industries, Textile Industries, Commercial buildings , AirLines, Gyms, Hydarulic machines, AC Plants, Call Centers Petrol Pumps, CNG stations and many more,

General :

Servo Voltage Stabilizer also called as Main Line Voltage corrector, Automotic Voltage Controller, SCVS,  Power  Corrector device  using synchronous motor in close loop control . It senses the Input variable voltage constantly through Microcontroller circuit and proportional voltage generates in buckboost and that adding & substracting is constantly monitoring by the closed loop system and regulated voltage given in output and get monitored by the display system construction is rigidly followed the IS 9815 norms

Servo Is facilitated by Auto & Manual Mode for self test purpose or for any customized applications.

Sr No

               Parameters

   Single Phase Servo

1Ph IN 1Ph O/P( P+N+G)

Three Phase Servo

1. 3Ph IN 3Ph O/P  ( 3P +N+G)

 2. 3Ph IN  (3P+N+G) &  1Ph O/P  (P+N+G)

1

      Capacity of Servo

Air cooled :  3 to 30 KVA

Oil cooled :  10 KVA to 75 KVA

Air cooled : 6 KVA to 75 KVA

Oil cooled : 30 KVA to 3000KVA

2

   Input Ranges  ( Fluctuation Range)

170 V to 280VAC

140 V to 300VAC

110VAC to 310VAC

340 VAC to 480VAC

300VAC to 500VAC

280VAC to 500VAC

260VAC to 500 VAC

240 VAC to 500VAC

3

Nominal Output Voltage

 230VAC

400/415 VAC Selectable

4

Output Voltage accuracy

±   1%

±   1%

5

Input Line frequency Variation

 47Hz to 53 Hz

47Hz to 53 Hz

6

Effect of Power Factor

  None

 None

7

Waveform Distortion

None Added (Same as Input)

None added ( Same as Input)

8

Control

Digital / Analogue

 Digital/ Analogue

9

Response Time

  10 msec

 10 msec

10

Voltage Correction Rate with Synchronous Motor

1 Air cooled

2 Oil cooled

 

 

  25V/Sec

  15V/Sec

 

 

 25V/Sec

 15V/Sec

11

LCD Display

Input Voltage , Output Voltage (L to L & L to N)

Phase wise current monitoring

12

Log book Memory ( Non Volatile)

  • No of Hrs of operation on mains peak current demand
  • No of abnormal High Voltage cutoff events
  • No of abnormal Low voltage cutoff events

13

Programmble Features ( By passwords)

  • HV cut-off Set
  • LV cut-off Set
  • O/L Trip Set
  • Time Delay Set
  • Operating mode ( Auto / Manual)

14

Cooling

1 Air  cooled

2. Oil cooled

 

     3 KVA to 75 KVA & Above

     10 KVA to 3000 KVA

15

Efficiency

    97 to 98%

16

Protections

Protection of all control parameters are through INPUT MCCB with Shunt release coil/ Output contactor in Lower capacity and cutoff protections available for

  • Input High & Low Voltage cutoff
  • Output Overvoltage & Under Voltage cutoff
  • Overload & short circuit protections
  • Single Phasing & Phase Loss Trip
  • Reverse Phase protections
  • Neutral fault protections
  • Earth Fault Protections

17

Class C/ TVSS Transient & Surge protections

  • Type 1+2 Type protections with UL 1449 CE compliances with guideline of earthings

3Ph-3Ph 45KVA to 3000KVA Oil-Cooled Servo

AC  Mainline voltage is unpredictably fluctuating in single phase & Three Phase Line, Our observation is, Variation in Mainline in a. Single phase from 100VAC to 300VAC( L/N) & in Three Phase the line variation is from : 240V to 500VAC ( L/L)

This fluctuation results into Low efficiency of the Load & equipments, Line Losses, Poor Power factor, Winding burn out, Armatures Failure & Lighting equipments wont give the desired result  .

Electric distribution is purely the Demand & supply match theorem, If it wont match fluctuation is bound to happen. Other reasons are improper cable selection, Loose connections etc. Fluctuation means the very Low , Low, Normal, High & Very High Line Voltage .

Due to Fluctuation either Low Voltage or High Voltage : We shall have the consequences

1. Frequent breakdown of the Electrical appliances : Motors/Furnaces/ Electronics/ Compressors etc

Although for partial Power stability is advised through IPFC or Capacitor in Inductive load, but its effectiveness also depends on the stable Voltage & that shall be perceived by the Servo Voltage Stabilizer.

Yes ! I am Interested

 

Types

1Ph  I/P &  1 Ph O/P  (P+ N+G)

  • Air cooled  Type
  • Oil Cooled Type

         Ranges up to : 75 KVA

 

 3 Ph  I/P & 3Ph O/P ( 3P+N+G)

  • Air cooled  UB Type
  • Oil cooled  UB Type

          Ranges Upto 3000 KVA

3Ph I/P (Delta) &  1Ph O/P  (P+N+G)

  • Aircooled 
  • Oilcooled

Ranges upto 1000 KVA

    ( Servo with integrated UIT )

It is made in regular model & also customized after your Load study to get the perfect result. Input Fluctuation range . The utility load detain , harmonic content these shall be the actual guideline to decide  the range & capacity as per IS 9815 Servo Construction norm

Purpose
  • Effectively control the voltage variation & fluctuations to prevent the damages of High Tech Instruments.
  • Excellent Energy saver device and recommended by BEE as Energy saver for Lighting Load applications
  • Value added Servo effectively controls the Transient Surges/Inrush current/High Voltage & Low Voltage protections subject to dedicated earthing.
  • Excellent neutral fault protections
  • Excellent Earth Fault protections
  • Transforming the infinite Raw Electrical Power into Finite protected Power
Salient Technical  Features
  • Analog / Microcontroller based Power corrector device with excellent protection with Instantaneous High Voltage/ Low Voltage/ Overload/Single phasing prevention/Reverse Phase protections/ Transient Surge suppressor (optional TVSS )
  • Stable output even under unbalanced voltage condition & Unbalanced load condition
  • Customized Input & Output voltage as per site and machines requirement.
  • Integrated Isolation Transformer  (optional) available with1.  1 Ph Input & 1Ph Output   2. 3 Ph Input , 3 Ph  Output  &  3.   3 Ph Input  &  1 Ph Output
  • Ratings available from 1 KVA to 3000KVA (Dimmer & Buck boost based with Rolling system)
  • Fast correction rate up to 70V/sec, Line to Line & 25V/Sec for 100KVA & above.
  • Response time of < 10 mSec
  • Use of PI control circuit or Microcontroller circuit prevents over/under shooting or hunting.
  • Plug –in type Glass epoxy control cards for ease serviceability.
  • Visual indication/protection against extreme Low & High Voltage conditions
  • Ruggedized construction, castor –mounted for easy movement
  • No waveform distortion, suitable for operation on DG set.
  • Auto/manual facility of operation from front panel controls.
  • Custom –built specification and all India service Network to meet OEM requirements
  • Optional built – in Ultra Isolation Transformer in normal/star –delta configuration
  • Power Saving up to 20% in Lighting Loads ( Condition applies).
  • Very effective in supporting the quality power
  • Designed for 24* 7* 365 cycle
  • Reduces overall maintenance cost by 80%
  • Payback period anticipated by 24 to 36 months
  • Life guarantee above 15 years
  • 80% depreciation
  • You can get the technical note on demand how power saving effectively works.
  • Entire Plant control by servo Voltage Regulators
  • CNC Machines/Plastic moulding machines/Spark Erosion & wirecut machines/
  • Residential applications
Applications :

 Rice & Flour Mills , Steel Industry, Machinery Industry, CNC Machines, Laser cutting Machines , Farm Houses & Resorts, Hospitals, Hotels, Show Rooms , Manufacturing Industries, Textile Industries, Commercial buildings , AirLines, Gyms, Hydarulic machines, AC Plants, Call Centers Petrol Pumps, CNG stations and many more,

General :

Servo Voltage Stabilizer also called as Main Line Voltage corrector, Automotic Voltage Controller, SCVS,  Power  Corrector device  using synchronous motor in close loop control . It senses the Input variable voltage constantly through Microcontroller circuit and proportional voltage generates in buckboost and that adding & substracting is constantly monitoring by the closed loop system and regulated voltage given in output and get monitored by the display system construction is rigidly followed the IS 9815 norms

Servo Is facilitated by Auto & Manual Mode for self test purpose or for any customized applications

Sr No

               Parameters

   Single Phase Servo

1Ph IN 1Ph O/P( P+N+G)

Three Phase Servo

1. 3Ph IN 3Ph O/P  ( 3P +N+G)

 2. 3Ph IN  (3P+N+G) &  1Ph O/P  (P+N+G)

1

      Capacity of Servo

Air cooled :  3 to 30 KVA

Oil cooled :  10 KVA to 75 KVA

Air cooled : 6 KVA to 75 KVA

Oil cooled : 30 KVA to 3000KVA

2

   Input Ranges  ( Fluctuation Range)

170 V to 280VAC

140 V to 300VAC

110VAC to 310VAC

340 VAC to 480VAC

300VAC to 500VAC

280VAC to 500VAC

260VAC to 500 VAC

240 VAC to 500VAC

3

Nominal Output Voltage

 230VAC

400/415 VAC Selectable

4

Output Voltage accuracy

±   1%

±   1%

5

Input Line frequency Variation

 47Hz to 53 Hz

47Hz to 53 Hz

6

Effect of Power Factor

  None

 None

7

Waveform Distortion

None Added (Same as Input)

None added ( Same as Input)

8

Control

Digital / Analogue

 Digital/ Analogue

9

Response Time

  10 msec

 10 msec

10

Voltage Correction Rate with Synchronous Motor

1 Air cooled

2 Oil cooled

 

 

  25V/Sec

  15V/Sec

 

 

 25V/Sec

 15V/Sec

11

LCD Display

Input Voltage , Output Voltage (L to L & L to N)

Phase wise current monitoring

12

Log book Memory ( Non Volatile)

  • No of Hrs of operation on mains peak current demand
  • No of abnormal High Voltage cutoff events
  • No of abnormal Low voltage cutoff events

13

Programmble Features ( By passwords)

  • HV cut-off Set
  • LV cut-off Set
  • O/L Trip Set
  • Time Delay Set
  • Operating mode ( Auto / Manual)

14

Cooling

1 Air  cooled

2. Oil cooled

 

     3 KVA to 75 KVA & Above

     10 KVA to 3000 KVA

15

Efficiency

    97 to 98%

16

Protections

Protection of all control parameters are through INPUT MCCB with Shunt release coil/ Output contactor in Lower capacity and cutoff protections available for

  • Input High & Low Voltage cutoff
  • Output Overvoltage & Under Voltage cutoff
  • Overload & short circuit protections
  • Single Phasing & Phase Loss Trip
  • Reverse Phase protections
  • Neutral fault protections
  • Earth Fault Protections

17

Class C/ TVSS Transient & Surge protections

  • Type 1+2 Type protections with UL 1449 CE compliances with guideline of earthings

Line Interactive UPS

Line Interactive UPS series from
Model
PE series UPS
Backup Time   Load Battery Type
PE600- IN
(Inbuilt battery)
15 Mins 1 PC 1* 7 AH
PE 1050 –IN   60 Mins 15 Mins 1 PC 4 PC 2*7AH 2* 7AH
PE1080 2 Hrs 1 PC 4*7AH
PE 1026 3 Hrs 1PC 2* 26AH
PE 1042 4 Hrs 1PC 2*42AH
PE 1065 6 Hrs 1PC 2*65AH
PE 2000SW 40Mins 2PC 4*7AH
Yes ! I am Interested
Features Line Interactive UPS
  • Line interactive with inbuilt AVR & surge filter control.
  • Fully digitized and microprocessor controlled
  • AVR Input Voltage range 145- 275 V (Range optional also)
  • Battery charging in UPS off mode
  • Cold start function (UPS can ON in battery mode also)
  • Buck & Boost AVR ( Auto voltage Regulation)
  • Short circuit & Overload protection
  • Advanced battery management Technology
  • Home away charging mode facility
Salient Features
  • Protection against Powerline surges,spikes,brownouts and blackouts.
  • AVR and audio alarm
  • Inbuilt sealed maintenance free batteries
  • External battery system available optionally.
APPLICATIONS
  • Home PCs,PCs & Computer Installations
  • LAN & Low end servers
  • Laser printers
  • Projectors
  • Routers
  • Educational Institutes
  • Scientific Instruments
  • Low budget office backup solutions.

True On Line HF UPS

Power is your Business Life Line . The more you have the better for your business growth & productivity & if not it may prove disastrous for your business, So, for uninterrupted Power security & performance  preserve it with online UPS. Our goal of zero defects and total customer satisfaction makes us the preferred suppl;ier for many major companies in the Electronics & Information Industries   . At our quality is measured by our products . Our sophisticated technology has enable us to cater to varied needs of Power distribution & backups. We provides a complete line of Power Electronics products. These include ON Line UPS  upto 500  KVA & more  , Battery Chargers, Solar UPS system, Servo Stabilizer & Solar Inverters . Moreover our vast Industry experience & our presence have enabled us to offer our technologically advanced Power solutions as per the requirements of our customer. As we lay considerable efforts to study the requirements & provide solution through continuously considerable efforts to study the requirements & provide solution through continuously upgraded product by our continual research & development so as to offer our client.

Yes ! I am Interested

                 1PH IN & 1PH OUT

         1KVA,2/3,5,6,7.5,10 & 15 KVA

 

                        3 PH IN & 1 PH OUT

             6KVA/240VDC 10,20KVA /360VDC

                        3 PH IN & 3PH OUT

           6/10/20/30/40/50/60KVA /360VDC

Features :

  • SPWM True ON Line Double conversion IGBT based  UPS  with output Galvanic Isolation Transformer
  • IGBT technology design
  • Pure Sine wave output
  • Bypass provided
  • Compact & well engineered architecture
  • Neutral Isolation Design
  • High Input Power factor > 0.97
  • Full bridge Inverter
  • Overload & Output short circuit protections
  • Wide Input tolerance range
  • Smooth & Silent operation
  • Fast correction rate for line & Load regulation
  • Compatible with the intelligent data protection package
  • Easy to install , use & maintain
  • Superior performance to price analysis
  • Full protection against Blackout, Brown Out , Surges, Spikes , Noise & sags
  • High MTBF , Static Switch or Manual Bypass switch available
  • Fully Redundancy is possible with HOT Standby Switch

DIGITAL SIGNAL PROCESSING

 Our UPS is fully digital adopting a signal processing Unit that integrated all power stages as well as control functions. The system uses only 2 cards as compared to a large number of control cards used in conventional UPS systems.  Signal Processing unit increases  system through increases reliability.

                                              TECHNICAL SPECIFICATIONS of ON Line UPS

   Capacity of UPS

     ON Line Series

  • 1 Phase Input & 1 Phase Output  ( P+N+G)

                1, 2/3 KVA, 5 KVA, 7.5 KVA,10 KVA & 15 KVA

  • 3 Phase Input(3P+N+G)  & 1Phase Output (P+N+G)

                 6 KVA/ 10 KVA/ 20 KVA/ 25 KVA

  • 3Phase Input(3P+N+G) & 3Phase Output( 3P+N+G)

                6/10/20/30/40/50/60 upto 200 KVA & Above

Design  Topology

SPWM True ON Line UPS IGBT based with Output Galvanic Isolation Transformer

 DC Link Voltage

                   36V/48/72/96/110/120/180/192/240 & 360 VDC

          DC Link Voltage depends on capacity & Topology of UPS

              ( Optional As per customer requirement and backup details)

 Design Construction

  • Modular construction for easy servicing
  • Troicalize to suit any working environment

INPUT

  • Single Phase : 160VAC to 280VAC
  • Three Phase :  370VAC to 470VAC on Mains

( On Above & Below range UPS shall run through battery)

Input Frequency Range

          45 Hz to 55 Hz

DC Link Voltage

 1IN 1OUT  : 1KVA : 36VDC , 2/3 KVA :48/72/96VDC , 7.5/10 /15 KVA : 180 or 192VDC

3IN 1OUT : 6/10/20/ 30 KVA : 240VDC or 360 VDC

3IN 3OUT : 6/10 : 240/360VDC  & 10/20 /30 to 60 KVA : 360VDC  & Above can be varied as per backup details

 

Battery Selection

17AH/26AH/42AH/65AH/100 AH/120 AH , 12V SMF VRLA Type battery and selection based on backup required

OUTPUT VOLTAGE

 

 Frequency

 230V± 1% Single Phase ( P+N+G)

400/415VAC ± 1% Three Phase ( 3P +N+G)

 50 Hz± 0.05 Hz

( Output frequency shall be in free running mode)

Line to Load Regulations

± 1% for DC I/P variation & O/P Load variation

Waveform

 Pure Sinewave

Load Power factor

 0.8 lagging to Unity

Harmonic distortion THDv

 < 3% for Linear Load & < 5% for Nonlinear load

Inverter Efficiency

93% for 360VDC , 90% for 180VDC & above & 85% approx : 48/72/96/110/120VDC

 Crest factor

     3:1

Overload

 125% for 5 Mins & 150% for 60 Sec

Transient Recovery

  Within 20 mSec ( 1Cycle)

Phase displacement

 120* ( For Three Phase Output)

Audible Noise

 Less than 50 db at 1 meter

Metering

Output Voltage ,Analog/ Digital  (Optional )

( As per customer choice) LED & Microprocessor based LCD metering for multiple parameter is provided

Operating Temperature

 0 to 50* C

Design Compliances

 IS 2026

 

This is Electrical critical UPS and can sustain any kind of Electrical environment

Major Applications

  • Home PCS, Servers, LAN & File Servers
  • OFFICE AUTOMATIONS
  • BANKING SECTOR, RAILWAYS & Financial Institutions
  • µProcessor based Instrumentations, Control Panels, PLC , Scada Systems,
  • Medical Equipments
  • Communication & Telecommunication Equipments
  • CNC Machines, Laser cutting Machines, Digital Printers,& Printing equipments
  • Health Sectors , Pharma Industries
  • Educational Institutes
  • Process Industries equipments
  • CCTV,CCTNS, Security & Surveillance equipments
  • Data Centres Small & Medium
  • Special purpose Machines
  • Industrial facility

True On Line LFISO UPS

Salient Features
  • Low Frequency IGBT based sinusoidal Double conversion with galvanic Isolation Transformer based sinusoidal PWM ON Line UPS.
  • Digital Sinusoidal pulse width modulation Technique, High Frequency Inverter operation
  • Power devices IGBT with double MCU based control circuit.
  • Pure sinusoidal output
  • THDv<3% & THDi<10% for Linear & Non Linear load
  • Wide Input range, Isolation Topology, withstanding with overloading makes it perfect Electrical critical Power conditioning equipment.
  • Effective protection from blackout, Brownout, surges, spikes, Noise & sags
  • Effective Transient Surge suppression with optional addition of TVSS
  • Excellent battery management system with high charging capacity can give the extra backup capacity and can achieve 4 Hrs backup capacity
  • High MTBF, Low operating cost
  • Static Transfer switch inbuilt
  • Soft powerwalk in and fuseless shortcircuit protection.
  • Efficiency better than 89%
  • Input PF>0.95 & Output LPF >0.8
Yes ! I am Interested
Availability

Available in range of 10KVA,20KVA,30 KVA,40KVA,60 KVA & 100KV

  • Isolation Transformer - 3 Phase-in 1 Phase-out
  • Isolation Transformer - 3 Phase-in 3 Phase-out
  • Industrial grid design
Application
  • For Servers
  • Educational Institutes
  • BFS
  • Healthcare Systems
  • Telecommunication Equipments
  • Small & Medium Data Centers
  • CNC Machines
  • Pharmaceutical Appliances
  • X-ray Machines
  • Industrial Facilities

Isolation And Ultra Isolation Transformer

ProtekG Power Electronics Pvt Ltd ( Protek Enterprises since 1996)  with brand protekG is one of the reputed manufacturer and exporter of  Isolation Transformer &  Ultra Isolation Transformer. Every process regarding manufacturing & quality control of each equipments is being done by a team of qualified & experienced engineers.

We are manufacturing the IT & UIT from 1 KVA to 1000 KVA or more in one Phase & Three Phase respectively.

This is two wind transformer with Air-cooled & Oil cooled type with multi shield copper wind.

Line Voltage nominal

a.   230VAC  : 230VAC  ( Single Phase/ Single Phase )

 b.   415VAC  : 415VAC ( Three Phase / Three Phase)

c.   415VAC  : 230VAC  ( Three Phase/ Single Phase)

Yes ! I am Interested

 Sr No

                                                                 ELECTRICAL SPECIFICATIONS

 

1

Type

Dry & Oil cooled Type, Isolation & Multi shield copper

 

2.

Configuration

Delta : Star / Star : Star

 

1IN : 1OUT , 3IN: 3OUT , 3IN : 1OUT

 

3.

Capacity

1KVA to  30 KVA  ( 1Ph IN/ 1Ph O/P)

 

6KVA to1000KVA  ( 3Ph IN / 3Ph O/P)

 

6 KVA to 300KVA  ( 3Ph IN / 1Ph O/P)

 

4.

INPUT

1Ph 230VAC

3Ph  415 V ( Delta or Star)

 

5

OUTPUT

1Ph 230VAC

1Ph 230VAC

3Ph 415VAC

6.

Isolation

Galvanic Isolation & Ultra Isolation Galvanic Transformer with multi

shield copper wind 2 coil Transformer

7.

Interwinding capacitance

< 0.05 mF or better in UIT

 

8

DC galvanic Isolation

200 M Ohms ( Winding to Winding & Winding to Gnd)

9

HV Test

Better than 1.5 KV for 1 Min

 

10

Load Regulation

Better than 5% from No Load to Full Load

 

11

Efficiency

Above 90%

 

12

CMRR

Better than 80dB

 

Applications :

  • Electrical Safety device
  • Used as Delta to Star conversion for Lighting applications
  • For UPS Output
  • For generating Local Phase, Neutral & Earth
  • Protection from Neutral Fault & earth fault

Lighting Transformer

Lighting Transformer

Yes ! I am Interested

CVT (Constant Voltage Transformer)

CVT (Constant Voltage Transformer)

Yes ! I am Interested

Manual Voltage Stabilizer (5KVA to 15KVA)

Manual Voltage Stabilizer (5KVA to 15KVA)

Yes ! I am Interested